Good Wholesale Vendors Rapid Visco Analyzer - High pressure,High temperature filtration – Taige
Good Wholesale Vendors Rapid Visco Analyzer - High pressure,High temperature filtration – Taige Detail:
TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
Name |
HTHP Filtration |
||||
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
Input Voltage |
AC220V±5% 50Hz |
||||
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
Mesh Area (cm2) |
22.6cm2 |
||||
Cup Capacity (ml) |
175ml |
500ml |
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
Weight (kg) |
75kg |
1.5kg |
1.9kg |
Power Supply |
AC220V±5% 50Hz |
— |
— |
Power(KW) |
1.2W |
— |
— |
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
Mesh Area (cm2) |
22.6cm2 |
— |
— |
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:
Related Product Guide:
Aubin | Oil Field Cementing Additives
Global Oil and Gas Chemicals Market 2018 growth Worldwide Forecast to 2025 | Stirred Fluid Loss Cell
Our enterprise since its inception, usually regards product top quality as business life, repeatedly enhance manufacturing technology, make improvements to product excellent and continuously strengthen enterprise total high quality administration, in strict accordance with all the national standard ISO 9001:2000 for Good Wholesale Vendors Rapid Visco Analyzer - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Luxembourg , Eindhoven , Miami , We've been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying products and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.
By Alan from Uzbekistan - 2015.09.08 17:09
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
By Alexandra from Belarus - 2015.10.01 14:14