China Manufacturer for Liquid Stirrer - High pressure,High temperature filtration – Taige
China Manufacturer for Liquid Stirrer - High pressure,High temperature filtration – Taige Detail:
TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
Name |
HTHP Filtration |
||||
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
Input Voltage |
AC220V±5% 50Hz |
||||
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
Mesh Area (cm2) |
22.6cm2 |
||||
Cup Capacity (ml) |
175ml |
500ml |
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
Weight (kg) |
75kg |
1.5kg |
1.9kg |
Power Supply |
AC220V±5% 50Hz |
— |
— |
Power(KW) |
1.2W |
— |
— |
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
Mesh Area (cm2) |
22.6cm2 |
— |
— |
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:
Related Product Guide:
New models for validating computational simulations of blood flow and damage in medical devices — ScienceDaily | Oil Field Cementing Additives
Cementing lab test, Operation & Practices
We attempt for excellence, provider the customers", hopes to be the most beneficial cooperation team and dominator enterprise for staff, suppliers and shoppers, realizes value share and continuous advertising for China Manufacturer for Liquid Stirrer - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Madras , Sydney , India , We have customers from more than 20 countries and our reputation has been recognized by our esteemed customers. Never-ending improvement and striving for 0% deficiency are our two main quality policies. Should you need anything, don't hesitate to contact us.
By Elma from Ecuador - 2015.06.21 17:11
This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
By Rose from Montreal - 2016.07.28 15:46